Description
FTTH Single-Armored outdoor duct drop cable, which is also called conduit fiber cable or underground fiber cable, is usually implemented by placing it inside underground ducts, and the
ducts are normally buried in the ground. To construct the cable, a bow-type FTTH indoor drop cable is placed in the middle of the cable. In order to suit for underground duct installation, a water – blocking tape and an aluminum armored tube cover the 2x3mm drop cable. Finally, a durable polyethylene (PE) jacket is added to create a round cable cross – section and lend added protection to the cable core.
Feature
- Soft and flexible, good bending performance
- Water-proof tape prevent the ingression of water into the cable
- AL-plastic tape makes the cable crush resistant and moisture proof
- FRP strength member improves the tensile strength, LSZH flame-retardant inner and outer jacket has good flame-retardant performance
- Special low-bend-sensitivity fiber provides high bandwidth and excellent communication transmission property
- Simple structure, light weight and high practicability
- Novel flute design, easily strip and splice, simplify the installation and maintenance
Cable Technical Data:
Fiber Count | 1F | 2F | 4F |
Strength member 1 | GFRP/KFRP | ||
0.5mm | |||
Strength member 2 | GFRP/KFRP/Solid Steel wire | ||
0.5mm | 0.5mm | 0.5mm | |
Cable diameter(mm) Approx. | 7.0±0.4mm | 7.0±0.4mm | 7.0±0.4mm |
Cable weight(kg/km) Approx | 40 | 40 | 40 |
Tensile Strength Short/ Long Term(N) | 1000/500 | ||
Crush resistance short/long term (N/100mm) | 1000/500 | ||
Operating temperature range(°C) | -40°C ~+70°C |
Main Mechanical and Environmental Performances
Items | Test Standard | Specified Value | Requirements |
Tension | IEC 60794-1-2-E1 | See Technical data | Additional attenuation:
≤0.4dB after test |
Crush | IEC 60794-1-2-E3 | See Technical data | Additional attenuation:
≤0.4dB after test |
Impact | IEC 60794-1-2-E4 | R=300mm, 10Nm,
one in 3 different places |
Additional attenuation:
≤0.4dB after test |
Repeated Bending | IEC 60794-1-2-E6 | R=30H | Additional attenuation:
≤0.4dB after test |
Temperature Cycling | IEC 60794-1-2-F1 | -40°C ~+70°C | Attenuation change:
≤0.4dB/km after test |
Optical fiber technical parameters-SM
Parameter | Conditions | Units | Value | |||
G652D | G657A1 | G657A2 | G657B3 | |||
Optical Specification | ||||||
Attenuation | 1310 nm | dB/km | ≤0.350 | ≤0.350 | ≤0.350 | ≤0.350 |
1383 nm | dB/km | ≤0.330 | ≤0.350 | ≤0.350 | ≤0.350 | |
1550 nm | dB/km | ≤0.210 | ≤0.210 | ≤0.210 | ≤0.210 | |
1625 nm | dB/km | ≤0.240 | ≤0.230 | ≤0.230 | ≤0.230 | |
Attenuation vs. Wavelength | 1310 nm VS. 1285-1330 nm | dB/km | ≤0.04 | ≤0.04 | ≤0.05 | ≤0.03 |
1550 nm VS. 1525-1575 nm | dB/km | ≤0.03 | ≤0.03 | ≤0.04 | ≤0.02 | |
1550 nm VS. 1480-1580 nm | dB/km | ≤0.04 | – | – | – | |
Zero Dispersion Wavelength | \ | nm | 1300-1324 | 1300-1324 | 1300-1324 | 1300-1324 |
Zero Dispersion Slope | ps/(nm2·km) | 0.073-0.092 | 0.073-0.092 | 0.073-0.092 | ≤0.092 | |
Dispersion | 1550 nm | ps/(nm·km) | 13.3-18.6 | 13.3-18.6 | 13.3-18.6 | |
1625 nm | ps/(nm·km) | 17.2-23.7 | 17.2-23.7 | 17.2-23.7 | ||
Polarization Mode Dispersion (PMD) | ps/√km | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | |
Cut-off Wavelength λcc | – | nm | ≤1260 | ≤1260 | ≤1260 | ≤1260 |
Mode Field Diameter (MFD) | 1310 nm | μm | 9.2±0.4 | 9.2±0.4 | 8.6±0.4 | 8.6±0.4 |
1550 nm | μm | 10.4±0.5 | 10.4±0.5 | 9.6±0.5 | 9.6±0.5 | |
Attenuation Discontinuity | 1310 nm | dB | ≤0.03 | ≤0.03 | ≤0.03 | ≤0.03 |
1550 nm | dB | ≤0.03 | ≤0.03 | ≤0.03 | ≤0.03 | |
Bidirectional Attenuation | 1310 nm | dB/km | ≤0.04 | ≤0.05 | ||
1550 nm | dB/km | ≤0.04 | ≤0.05 | |||
Geometrical | ||||||
Cladding Diameter | μm | 125±0.7 | 125±0.7 | 125±0.7 | 125±0.7 | |
Cladding Non-Circularity | % | ≤1.0 | ≤1.0 | ≤0.8 | ≤0.7 | |
Core/Cladding Concentricity Error | μm | ≤0.6 | ≤0.5 | ≤0.5 | ≤0.5 | |
Coating Diameter (Uncolored) | μm | 242±7 (standard) | ||||
μm | 200±10 (optional) | |||||
Coating/Cladding Concentricity Error | μm | ≤12 | ≤12 | ≤12 | ≤12 | |
Curl | m | ≥4 | ≥4 | ≥4 | ≥4 | |
Environmental (1550nm, 1625nm) | ||||||
Temperature Cycling | -60℃ to +85℃ | dB/km | ≤0.03 | ≤0.05 | ≤0.05 | ≤0.05 |
High Temperature &
High Humidity |
85℃, 85% RH, 30days | dB/km | ≤0.03 | ≤0.05 | ≤0.05 | ≤0.05 |
Water Immersion | 23℃, 30days | dB/km | ≤0.03 | ≤0.05 | ≤0.05 | ≤0.05 |
High Temperature Aging | 85℃, 30days | dB/km | ≤0.03 | ≤0.05 | ≤0.05 | ≤0.05 |
Application:
Used in aerial and duct access cabling
Can be installed in small bending environment
Suitable for the connection between indoor and outdoor
Specially used where good insulation performance are expected
Ideal Solution For FTTH Drop Cable Use
With low smoke, zero halogen and flame retardant inner and outer jacket, this cable can be especially used in aerial and duct access cabling, suitable for the connection between indoor and outdoor. It can also be directly terminated connecting to communication equipment.